Lower Static Pressures

Lower Static PressuresUsing Air Zone column units without underfloor ductwork will result in even lower static pressures due to our efficient cabinet design and direct drive plenum fan.

One of the advantages of underfloor systems is lower operating static pressure, which results in lower fan energy. Air Zone’s column units are carefully selected for optimal performance and operate with lower pressure, thereby consuming less fan horsepower.

In order to better assist the engineer in calculating the unit static pressure, we have provided a typical unit static pressure for an environmental air tower with a cooling coil. Please note that in order to guarantee NC 40 sound performance at the maximum airflow condition (refer to sound test data), the Total Static Pressure at the column unit should be 1.5” or lower.

PRIMARY AIR MIXING DAMPERS LOSS: 0.10
FILTER ALLOWANCE: 0.75
FAN INLET LOSS: 0.07
SAMPLE COOLING COIL PRESS. LOSS: 0.21
INTERNAL STATIC LOSS: 1.13
RETURN AIR STATIC LOSS: .25
UNDERFLOOR STATIC PRESSURE: .05
TOTAL STATIC PRESSURE: 1.43

One of the advantages of underfloor systems is lower operating static pressure, which results in lower fan energy.
PRINTABLE VERSION
CONTACT AIR ZONE
NEWSLETTER SUBSCRIPTION

 

The Brains of the Operation
In the July Issue of Engineered Systems Magazine, Julie DeNardis with ESD talks about the HSBC project in Chicago which utilized Air Zone’s Mixed Flow Column Units.

Lights Out Houston
Air Zone was proud to once again be an organizing sponsor for Lights Out Houston 2009. Over 111 Million SF of building property managers and tenants pledged to forever turn off unnecessary lighting – visit www.lightsouthouston.com for more information.

Air Zone Tower Units Go in one of the world’s most energy efficient skyscrapers.
National Geographic takes you behind the scenes of One Bryant Park.

3 New Downtown Office Towers in Houston and Denver are awarded to Air Zone International.
Each of these green projects features our custom air handling units for overhead distribution.

Air Zone teams with Tate in joint marketing initiative.
An initiative that will offer quiet, compact and energy efficient supply air to underfloor service distribution systems.

Hess Explores Discovery Tower
A likely candidate considers entire 30-stories, of which Air Zone International manufactured the air units.

Architecture 2030 Mission
Immediate action required to reverse buildings' emissions.

© 2012, Air Zone International

5220 Ted Street   |   Houston, Texas 77040   |   office (713) 460-4040   |   fax (713) 460-4050